Title reads like at ad, but this is a new way to reach energy independence. I actually have a small EcoFlow device and it’s pretty good for the price.

I hope this tech can be made available in the US soon.

  • deafboy@lemmy.world
    link
    fedilink
    English
    arrow-up
    0
    ·
    7 months ago

    Plug-in systems are built around a microinverter that feeds solar energy back into the home via a standard wall jack.

    What the actual fuck?

    The PowerStream has three proprietary ports: one that connects to your MC4 solar panels

    Disqualified.

    • Andromxda 🇺🇦🇵🇸🇹🇼@lemmy.dbzer0.com
      link
      fedilink
      English
      arrow-up
      0
      ·
      7 months ago

      Plug-in systems are built around a microinverter that feeds solar energy back into the home via a standard wall jack.

      What the actual fuck?

      What’s wrong with that? That’s how basically any balcony solar system works.

      • Sleepkever@lemm.ee
        link
        fedilink
        English
        arrow-up
        0
        ·
        7 months ago

        The cables in your walls are designed for a certain maximum current before they start to heat up. This current is limited by your breaker.

        Now if you introduce a plug in solar setup your current is limited by your maximum breaker capacity + whatever your solar setup can generate.

        So if I’d use the specs from the article and apply it to a normal dutch home situation: 16A breaker, + 800W at 230V, which means ~3.5A = 19.5A max. which is probably still fine for short durations.

        But now some genius doesn’t read the fine print and hooks up 2 or 3 on the same circuit. There is no electrician that tells him that’s dangerous because it’s all self installed and he doesn’t know any better. And all of a sudden you are up to 26.5A and you got glowing, smoking wires in your walls…

        • Andromxda 🇺🇦🇵🇸🇹🇼@lemmy.dbzer0.com
          link
          fedilink
          English
          arrow-up
          0
          ·
          7 months ago

          But now some genius doesn’t read the fine print and hooks up 2 or 3 on the same circuit. There is no electrician that tells him that’s dangerous because it’s all self installed and he doesn’t know any better. And all of a sudden you are up to 26.5A and you got glowing, smoking wires in your walls…

          Ok sure, that makes sense. This might actually be an issue.

        • Brkdncr@lemmy.worldOP
          link
          fedilink
          English
          arrow-up
          0
          ·
          7 months ago

          Your breaker will pop. Just like if you were to run a hair dryer on each outlet.

          • Sleepkever@lemm.ee
            link
            fedilink
            English
            arrow-up
            0
            ·
            7 months ago

            The breaker only sees the current flowing through the breaker though. Not the additional current provided by the solar panels since those don’t flow through the breaker. So it will pop later then that the cables are rated for, therefore introducing an overheat and fire hazard.

            • Brkdncr@lemmy.worldOP
              link
              fedilink
              English
              arrow-up
              0
              ·
              7 months ago

              Maybe for a same-circuit device that’s consuming more than the breaker can provide? I don’t know enough about this tech but would expect this can be accounted for in some way.

    • helenslunch@feddit.nl
      link
      fedilink
      English
      arrow-up
      0
      ·
      6 months ago

      Proprietary, overpriced, with flashy visuals and apps, and a massive marketing budget. They’re the Apple of solar generators.

    • Bizarroland@kbin.social
      link
      fedilink
      arrow-up
      0
      ·
      7 months ago

      That happens quite a bit in a lot of areas. It sounds stupid but your toaster does not care where the electricity it is using comes from.

      As long as the sine waves are in sync with each other then you have nothing to worry about.

      It’s probably not standard in America because the technology is newer and the regulations haven’t caught up.

      • ArbiterXero@lemmy.world
        link
        fedilink
        English
        arrow-up
        0
        ·
        7 months ago

        2 problems….

        1. If you forget to turn off the mains, it could really make a lineman unhappy.

        2. Most of these setups require a reprimand dangerous “ suicide cord”

        • Bizarroland@kbin.social
          link
          fedilink
          arrow-up
          0
          ·
          7 months ago

          The first problem is solved by line sensing technology. If there is not power coming in and off of the switch then the inverter will not pump energy back into the system, at least on the ones that are not $12 cheap Chinese junk off of taobao.

          And rather than suicide cords they generally have an IEC connector (standard rhombusy shaped computer power connector) on one end and a normal prong on the other.

          But you are right that it is dangerous and not recommended to anyone, especially the people that are not smart enough to take the appropriate concerns and considerations into mind before using it.

          • ArbiterXero@lemmy.world
            link
            fedilink
            English
            arrow-up
            0
            ·
            7 months ago

            I’d be super disappointed by owning a solar cell and not being able to use it during a power outage.

            • Bizarroland@kbin.social
              link
              fedilink
              arrow-up
              0
              ·
              7 months ago

              That’s a pretty standard issue with grid tied solar systems. You save a lot of money by not having batteries, but when the neighborhood goes down you go down with it.

              Plus you don’t want to be pumping electricity into a downed power system, you could actually end up hurting a line man who is working on the system.

              However, and both of these issues can be resolved by adding in a generator and a whole house cut off system.

              In a power outage scenario, all you would have to do is throw the crossover switch and crank the generator. The generator would produce enough energy to reactivate the solar system.

        • mxcory@lemmy.blahaj.zone
          link
          fedilink
          English
          arrow-up
          0
          ·
          7 months ago

          I know enphase micro inverters have “anti-islamding” tech that disables output when they lose grid connection. I would expect any reputable manufacturer to also have the same tech.

          I don’t expect that for backup generators, but the proper way for them is via a transfer switch. You can wire in a properly made cable instead of a suicide cable. The transfer switch would prevent the inlet connector to the house from ever being live. (And since it is a proper cord from the generator, there would be no exposed ends coming from it.)

          • ArbiterXero@lemmy.world
            link
            fedilink
            English
            arrow-up
            0
            ·
            7 months ago

            I agree on all points, but honestly I’d be pretty upset if I got a solar setup that didn’t work when the power was out haha

            • mxcory@lemmy.blahaj.zone
              link
              fedilink
              English
              arrow-up
              0
              ·
              7 months ago

              There is still a solution for that, solar + battery. I would love to have one myself, but solar alone can be a bit expensive on its own.

              • Serinus@lemmy.world
                link
                fedilink
                English
                arrow-up
                0
                ·
                7 months ago

                A battery is ~$8300 - 10k. It’s amazing how many places will try to charge $16k.

                • Juvyn00b@lemmy.world
                  link
                  fedilink
                  English
                  arrow-up
                  0
                  ·
                  7 months ago

                  48v 100ah battery with Bluetooth BMS built in is around 700$ on ali express… Slightly more direct from Amazon in the USA if you want it fast. Will store close to 5kwh which I guarantee you beats out this solution. Of course you’d still need to buy the grid sync inverter (available in many places) as well as a solar mppt charger and solar cells. Still will come below this cost - or you’ll simply blow by the capacity of what you would have paid for this solution. But gotta have the old noggin on straight to do it yourself.

                  • Serinus@lemmy.world
                    link
                    fedilink
                    English
                    arrow-up
                    0
                    ·
                    7 months ago

                    If it was that easy to do it right, you’d have small businesses offering to do it for thousands, instead of the current going rates, which is tens of thousands.

                • emeralddawn45@discuss.tchncs.de
                  link
                  fedilink
                  English
                  arrow-up
                  0
                  ·
                  7 months ago

                  Yes it is if you read the article, that’s exactly how he had it set up, and then you just have to manually move the battery where power is needed. You just can’t use your wall outlets when there’s an outage.

        • Fuck spez@sh.itjust.works
          link
          fedilink
          English
          arrow-up
          0
          ·
          7 months ago

          You’re also likely to repeatedly trip whatever breaker that outlet is connected to unless it’s a big one like you’d have for a central AC unit, but then you’d likely also know enough to have a proper transfer switch.

        • hedidwot@lemmynsfw.com
          link
          fedilink
          English
          arrow-up
          0
          ·
          7 months ago

          If it has anti islanding at least it’s unlikely to be a shock hazard.

          That said are there any other concerns I’m missing?

      • greentreerainfire@kbin.social
        link
        fedilink
        arrow-up
        0
        ·
        7 months ago

        Yeah. My grandfather (former electrician and electrical inspector) had a specific outlet he’d plug a gas generator in to back feed power into the house. This was in the 80s and 90s.

        He also pointed out that he turned the main off so it did not back feed into the grid and power lines that a lineman is expecting to not be live.

        • Valmond@lemmy.world
          link
          fedilink
          English
          arrow-up
          0
          ·
          7 months ago

          Thanks for the info, very interesting!

          I wonder if just plugging a power source in a socket would work in a more modern setting?

          Had all electricity redone last year, there was some crazy stuff from the fifties, a hot line going everywhere, just plug into it and ground it, power everywhere 😵‍💫. Guess I could have plugged some power in anywhere (cutting off the mains).

          Now there are differential and fuses for every applience etc.

          • towerful@programming.dev
            link
            fedilink
            English
            arrow-up
            0
            ·
            7 months ago

            If you want to power your house independently from the grid, your house has to be independent from the grid.
            Anything where you sell your excess power back to the grid is in tight cooperation with the grid operators.

            Standard house wiring is not set up to accommodate back feeding the grid nor independently powering.
            So you will need a changeover switch professionally fitted if you want an independent power source, or your solar panel installers will fit the appropriate equipment to back-feed the grid.
            Anything else will likely involve deaths, fires, broken equipment, criminal prosecution, insurance invalidation and all that nasty stuff.

        • ramble81@lemm.ee
          link
          fedilink
          English
          arrow-up
          0
          ·
          7 months ago

          Yeah my parents house had an rv/generator hookup and it had a huge bar across both the breakers so power could only flow in one direction. If you hooked up a generator it would cut the house off from the mains.

        • corsicanguppy@lemmy.ca
          link
          fedilink
          English
          arrow-up
          0
          ·
          edit-2
          7 months ago

          Your grandfather’s extra outlet for the alternate feed was the other half of a switch that flipped over when the mains power died. It shuts off the power connection to the house by flipping over and ensures no power goes back over the line, among other things. We have these - albeit the size of a washing machine - in really big datacenters.

        • sugartits@lemmy.world
          link
          fedilink
          English
          arrow-up
          0
          ·
          7 months ago

          From the article:

          And when there’s a power outage, the PowerStream will turn off automatically to ensure there’s no electricity in the wires in order to protect line workers from shock. The PowerStream will only turn back on when the grid power returns.

        • Hugh_Jeggs@lemm.ee
          link
          fedilink
          English
          arrow-up
          0
          ·
          7 months ago

          You realise it’s new tech and probably needs a proprietary connection?

          Did you disqualify ebikes too when they appeared?

          • grue@lemmy.world
            link
            fedilink
            English
            arrow-up
            0
            ·
            7 months ago

            LOL, no, pretty much nothing ever “needs” a proprietary connection these days. Certainly not a fucking plain old power connection for a solar panel!

            • Hugh_Jeggs@lemm.ee
              link
              fedilink
              English
              arrow-up
              0
              ·
              7 months ago

              It’s not just for the panel though, it’s for switching between feeding an outlet and supplying an appliance, looks pretty intelligent to me

              But I live in the EU, if they make it proprietary for no reason, they’ll get told to fuck off rather quickly 😂

              • nickwitha_k (he/him)@lemmy.sdf.org
                link
                fedilink
                English
                arrow-up
                0
                ·
                7 months ago

                There are a TON of standardized power connectors available that enable compatibility with off-the-shelf parts. Seriously, just look on Mouser or DigiKey. The only reason for proprietary connectors in this case is to try to obtain vendor lock-in.